Sign In | Join Free | My himfr.com
Home > Digital I O Module >

1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module

    Buy cheap 1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module from wholesalers
     
    Buy cheap 1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module from wholesalers
    • Buy cheap 1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module from wholesalers
    • Buy cheap 1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module from wholesalers

    1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module

    Ask Lasest Price
    Brand Name : AB
    Model Number : 1746-NO8V
    Price : negitiation
    Payment Terms : T/T, Western Union
    Supply Ability : 100
    Delivery Time : 3-5days
    • Product Details
    • Company Profile

    1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module

    1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module


    Technical Specifications for 1746-NO8V
    Manufacturer Rockwell Automation
    Optional Output Data Parameters User defined scale limits Output clamping limit Output alarm limits Ramp rate/limit Preset fault value Output behavior under fault condition (reset, hold, preset) Alarms latch Reset latched alarms
    SLC Data Formats Scaled engineering units Scaled for PID Proportional counts 1746-NO4 format User-defined scale
    Backplane Power consumption 5.6W
    Backplane current consumption 120 mA at 5V dc 160 mA at 24V dc (J4 jumper set to RACK) 0 mA at 24V dc (J4 jumper set to EXT)
    Compatible chassis Any 1746 chassis slot except slot 0
    Output coding -32,768 to +32,767
    Output voltages -10 to +10VDC; -10.25 to +10.25VDC; 0 to 10VDC; 0 to 5VDC and 1 to 5VDC.
    Output wiring Single-ended
    Brand AB
    Part Number/Catalog No. 1746-NO8V
    Series SLC 500
    Module Type Analog output module
    Resolution 16-bit 320 µV/count
    Outputs 8
    Backplane Current (5 Volts) 120 milliamps
    Backplane Current (24 Volts) 160 milliamps
    Update Time 540 microseconds/8 channel
    Step Response 1 millisecond
    Step Response 60 milliseconds in, 2.5 milliseconds out
    UPC 10781180054560
    UPC 10781180054577


    OTHER SUPERIOR PRODUCTS

    Yasakawa Motor, Driver SG-Mitsubishi Motor HC-,HA-
    Westinghouse Modules 1C-,5X-Emerson VE-,KJ-
    Honeywell TC-,TK-GE Modules IC -
    ABB ModuleAB Module 1756-,1759- Tourch Screen 2711-
    Mitsubishi Drive MR- , Motor HA -,HCEmerson MoudlesVE- ,KJ -
    Fanuc motor A0-, DriveYokogawa transmitter EJA-
    Rosemount Transmitter 3051-Schneider Module 140-
    Panasonic Motor , Drive MH-Siemens Module 6ES-, Touch Screen 6AV-

    EtherNet/IP Network Configuration
    EtherNet/IP Communication Modules
    1756-ENBT, 1756-EN2F, 1756-EN2T, 1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT, 1756-EN2TR, 1756-EN2TRXT,
    1756-EN2TSC, 1756-EN2TXT, 1756-EN3TR, 1756-EWEB, 1768-ENBT
    CompactLogix 5370 Controllers
    EtherNet/IP Adapters
    1734-AENT, 1734-AENTR, 1769-AENTR, 1794-AENT, 20-COMM-E, 22-COMM-E, 20-750-ENETR
    Embedded Switches
    1783-ETAP, 1783-ETAP1F, 1783-ETAP2


    The AB 1746-C7 cable is a ribbon power cable that connects controllers and chassis. The spacing between the controllers and chassis are important to note. When using the 1746-C7 cable to connect SLC 500 controllers, the space between them should be between 2.5 and 4 inches. When using the cable to connect AB 1746-P4 power supplies, the maximum spacing between the supplies is 2.5 inches. The 1746-C7 cable itself measures 6 inches in length. It should only be used to connect chassis and controllers side by side, not in a stacked formation with one chassis or controller above the other.



    The 1746-C7 cable is best-suited for connecting AB 1746-A4, 1746-A7, 1746-10, and 1746-A13 chassis. The cable can connect these chassis in any combination with each other (for example, the 1746-C7 cable can connect 2 1746-A4 chassis to each other, it can connect 1 1746-A4 chassis to any of the other chassis listed).



    FAQ for 1756-PB75
    What is the difference between the 1756-PA75 and 1756-PB75?


    The 1756-PA75 operates when supplied with 85-264VAC while the 1756-PB75 is powered by an external 18-32VDC supply voltage.

    Can I use this power supply as voltage source of panel components?


    No. This power supply is intended only for the ControlLogix chassis.

    What are compatible ControlLogix chassis for use with the 1756-PB75?


    Compatible chassis are 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17.


    Quality 1746-NO8V AB 16-bit 320 µV/count SLC 500 analog output module for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)