    Brand Name : ROSEMOUNT
    Model Number : 3051CFPDS010W1S0500D32AA1E5M5
    Price : Negotiate
    Payment Terms : T/T,PAYONEER
    Supply Ability : 10EA,8weeks
    Delivery Time : 8 WEEKS
    Certification : Does not supply
    • Product Details
    • Company Profile

    3051CFPDS010W1S0500D32AA1E5M5 Pressure Temperature Transmitter

    3051CFPDS010W1S0500D32AA1E5M5 Integral Orifice Flow Meter 3051CFP Transmitter


    Product Information Of : 3051CFPDS010W1S0500D32AA1E5M5

    Brand3051CFPDS010W1S0500D32AA1E5M5
    SUPPLY

    0 to 621,60 mbar

    SIZENo
    WeightDoes not supply

    Rosemount 3051CFP Integral Orifice Flow Meters enable highly accurate flow measurement in small line sizes. Integral Orifice Flow Meters use precision honed pipe section for increased accuracy and self-centering plate design to prevent alignment errors that magnify measurement inaccuracies in small line sizes.
    ■Up to 1.75 percent of flow rate accuracy.
    ■Available in ½- to 1½-in. (15 - 40 mm) line sizes.
    ■Fully assembled and leak tested for out-of-the-box installation.
    ■The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
    ■LOI with straightforward menus and built-in configuration buttons (option code M4).


    More options :

    SGDA-04BS

    SGDA-04VP

    SGDA-04VP

    SGDA-04VS

    SGDA-05ADG+SGMG-05A2A

    SGDA-08AP

    SGDA-08APP

    SGDA-08APPY128

    SGDA-08AS

    SGDA-08ASP

    SGDA-08ASP SGDA-08AS

    SGDA-08VP

    SGD-A3AN

    SGD-A5AN

    SGD-A5BH

    SGDA-A3AP

    SGDA-A3BPM

    SGDA-A3BS

    SGDA-A3BS

    SGDA-A3CPY14


    MR-J2S-350B-EG117

    MDS-B-SVJ2-01

    MDS-B-SVJ2-03

    MDS-B-SVJ2-04

    MDS-B-SVJ2-06

    MDS-B-SVJ2-10

    MDS-B-SVJ2-20

    MDS-B-SVJ2-07

    MDS-D-SVJ3-01NA

    MDS-D-SVJ3-02NA

    MDS-D-SVJ3-07NA

    MDS-D-SVJ3-10NA

    MDS-D-SVJ3-20NA


    Rosemount 3051CFP Integral Orifice Flow Meter​ Information:

    ModelProduct description
    3051CFPIntegral orifice flow meter
    Measurement type
    DDifferential pressure
    Body material
    S316 SST
    Line size
    005½-in. (15 mm)
    0101-in. (25 mm)
    0151½-in. (40 mm)
    Process connection
    T1NPT female body (not available with remote thermowell and RTD)
    S1(1)Socket weld body (not available with remote thermowell and RTD)
    P1Pipe ends: NPT threaded
    P2Pipe ends: beveled
    D1Pipe ends: Flanged, DIN PN16, slip-on
    D2Pipe ends: Flanged, DIN PN40, slip-on
    D3Pipe ends: Flanged, DIN PN100, slip-on
    W1Pipe ends: Flanged, RF, ANSI Class 150, weld-neck
    W3Pipe ends: Flanged, RF, ANSI Class 300, weld-neck
    W6Pipe ends: Flanged, RF, ANSI Class 600, weld-neck
    A1Pipe ends: Flanged, RF, ANSI Class 150, slip-on
    A3Pipe ends: Flanged, RF, ANSI Class 300, slip-on
    A6Pipe ends: Flanged, RF, ANSI Class 600, slip-on
    R1Pipe ends: Flanged, RTJ, ANSI Class 150, slip-on
    R3Pipe ends: Flanged, RTJ, ANSI Class 300, slip-on
    R6Pipe ends: Flanged, RTJ, ANSI Class 600, slip-on
    Orifice plate material
    S316 SST
    HAlloy C-276
    MAlloy 400
    Bore size option
    00660.066-in. (1.68 mm) for ½-in. pipe
    01090.109-in. (2.77 mm) for ½-in. pipe
    01600.160-in. (4.06 mm) for ½-in. pipe
    01960.196-in. (4.98 mm) for ½-in. pipe
    02600.260-in. (6.60 mm) for ½-in. pipe
    03400.340-in. (8.64 mm) for ½-in. pipe
    01500.150-in. (3.81 mm) for 1-in. pipe
    02500.250-in. (6.35 mm) for 1-in. pipe
    03450.345-in. (8.76 mm) for 1-in. Pipe
    05000.500-in. (12.70 mm) for 1-in. pipe
    06300.630-in. (16.00 mm) for 1-in. pipe
    08000.800-in. (20.32 mm) for 1-in. pipe
    02950.295-in. (7.49 mm) for 1½-in. pipe
    03760.376-in. (9.55 mm) for 1½-in. pipe
    05120.512-in. (13.00 mm) for 1½-in. pipe
    07480.748-in. (19.00 mm) for 1½-in. pipe
    10221.022-in. (25.96 mm) for 1½-in. pipe
    11841.184-in. (30.07 mm) for 1½-in. pipe
    00100.010-in. (0.25 mm) for ½-in. pipe
    00140.014-in. (0.36 mm) for ½-in. pipe
    00200.020-in. (0.51 mm) for ½-in. pipe
    00340.034-in. (0.86 mm) for ½-in. pipe
    Transmitter connection platform
    D3Direct-mount, 3-valve manifold, SST
    D5Direct-mount, 5-valve manifold, SST
    R3Remote-mount, 3-valve manifold, SST
    R5Remote-mount, 5-valve manifold, SST
    D4Direct-mount, 3-valve manifold, alloy C-276
    D6Direct-mount, 5-valve manifold, alloy C-276
    D7Direct-mount, high temperature, 5-valve manifold, SST
    R4Remote-mount, 3-valve manifold, alloy C-276
    R6Remote-mount, 5-valve manifold, alloy C-276
    Differential pressure ranges
    10 to 25 in H2O (0 to 62,16 mbar)
    20 to 250 in H2O (0 to 621,60 mbar)
    30 to 1000 in H2O (0 to 2,48 bar)
    Transmitter output
    A(2)4–20 mA with digital signal based on HART® Protocol
    FFOUNDATION™ Fieldbus Protocol
    W(3)PROFIBUS® PA Protocol
    X(4)Wireless
    M(5)Low-power 1–5 Vdc with digital signal based on HART Protocol
    Transmitter housing materialConduit entry size
    AAluminum½–14 NPT
    BAluminumM20 x 1.5
    EAluminum, ultra low copper½–14 NPT
    FAluminum, ultra low copperM20 x 1.5
    JSST½–14 NPT
    KSSTM20 x 1.5
    P(6)Engineered polymerNo conduit entries
    D(7)Aluminum
    M(7)SST
    Transmitter performance class
    1up to ±1.8% flow rate accuracy, 8:1 flow turndown, 5-year stability
    Wireless options (requires wireless output code X and engineered polymer housing code P)
    Wireless transmit rate, operating frequency, and protocol
    WA3User configurable transmit rate, 2.4GHz WirelessHART
    Antenna and SmartPower
    WP5Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
    Options (include with selected model number)
    Extended product warranty
    WR33-year limited warranty
    WR55-year limited warranty
    Transmitter body/bolt material
    GTHigh temperature (850 °F/454 °C)
    Temperature sensor(8)
    RTThermowell and RTD
    Optional connection
    G1DIN 19213 transmitter connection
    Pressure testing(9)
    P1Hydrostatic testing with certificate
    Special cleaning
    P2Cleaning for special services
    PACleaning per ASTM G93 level D (section 11.4)
    Material testing
    V1Dye penetrant exam
    Material examination
    V2Radiographic examination
    Flow calibration(10)
    WDDischarge coefficient verification
    Special inspection
    QC1Visual and dimensional inspection with certificate
    QC7Inspection and performance certificate
    Material traceability certification
    Q8Material traceability certification per EN 10204:2004 3.1
    Code conformance(11)
    J2ANSI/ASME B31.1
    J3ANSI/ASME B31.3
    J4ANSI/ASME B31.8
    Materials conformance(12)
    J5NACE MR-0175/ISO 15156
    Country certification
    J6European Pressure Directive (PED)
    J1Canadian Registration
    Transmitter calibration certification
    Q4Calibration Certificate for Transmitter
    Quality certification for safety(13)
    QSPrior-use certificate of FMEDA data
    QTSafety certified to IEC 61508 with certificate of FMEDA
    Product certifications
    E8ATEX Flameproof, Dust
    I1(14)ATEX Intrinsic Safety and Dust
    IAATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    N1ATEX Type n and Dust
    K8ATEX Flameproof, Intrinsic Safety, Type n, and Dust (combination of E8, I1, and N1)
    E5FM Explosion-proof, Dust Ignition-proof
    I5(15)FM Intrinsically Safe, Nonincendive
    IEFM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K5FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5)
    C6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
    I6 (6)CSA Intrinsically Safe
    K6CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
    E7IECEx Flameproof, Dust Ignition-proof
    I7IECEx Intrinsic Safety
    N7IECEx Type n
    K7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
    E2INMETRO Flameproof
    I2INMETRO Intrinsic Safety
    IBINMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K2INMETRO Flameproof, Intrinsic Safety
    E3China Flameproof
    I3China Intrinsic Safety
    KBFM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
    KDCSA, FM, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
    Sensor fill fluid and O-ring options
    L1(16)Inert sensor fill fluid
    L2Graphite-filled (PTFE) O-ring
    LA(16)Inert sensor fill fluid and graphite-filled (PTFE) O-ring
    Shipboard approvals(16)
    SBSAmerican Bureau of Shipping
    SLL(17)Lloyds Register (LR)
    Display and interface options
    M4(18)LCD display with LOI
    M5LCD display
    Transient protection(16)(19)
    T1Transient terminal block
    Plantweb control functionality(20)
    A01FOUNDATION Fieldbus control function block suite
    Plantweb diagnostic functionality
    DA0(13)Loop Integrity HART Diagnostic
    D01(20)FOUNDATION Fieldbus diagnostic suite
    Low power output
    C20.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
    Alarm levels(13)
    C4(21)NAMUR alarm and saturation levels, high alarm
    CN(21)NAMUR alarm and saturation levels, low alarm
    CRCustom alarm and saturation signal levels, high alarm
    CSCustom alarm and saturation signal levels, low alarm
    CTRosemount standard low alarm
    Ground screw(16) (22)
    V5External ground screw assembly
    Configuration buttons
    D4(13)Analog zero and span
    DZ(23)Digital zero trim
    Hart Revision configuration (requires HART Protocol output code A)(2)
    HR5Configured for HART Revision 5
    HR7Configured for HART Revision 7
    Typical model number: 3051CFP D S 010 W1 S 0500 D3 2 A A 1 E5 M5

    Good Service in WTL:
    > We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
    > Please send your RFQ to get the latest price.
    > Normally, we will ship the items in 1-2 weeks after receive the payment.
    > We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
    > We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.