Sign In | Join Free | My himfr.com
Home > Pressure Temperature Transmitter >

3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level Measurement

Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level Measurement from wholesalers
     
    Buy cheap 3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level Measurement from wholesalers
    • Buy cheap 3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level Measurement from wholesalers
    • Buy cheap 3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level Measurement from wholesalers

    3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level Measurement

    Ask Lasest Price
    Brand Name : ROSEMOUNT
    Model Number : 3051L2AA0D21AAF1
    Price : Negotiate
    Payment Terms : T/T,PAYONEER
    Supply Ability : 50EA,8weeks
    Delivery Time : 4-6WEEKS
    Certification : Does not supply
    • Product Details
    • Company Profile

    3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level Measurement

    3051L2AA0D21AAF1 Level Transmitter Rosemount 3051L Transmitter


    Product Information Of: 3051L2AA0D21AAF1

    Brand3051L2AA0D21AAF1
    SUPPLY

    0 to 621,60 mbar

    SIZEDoes not supply
    Weight5KG

    (1)Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.

    (2)Option code M4 - LCD display with LOI required for local addressing and configuration.

    (3)Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), IECEx Intrinsic Safety (option code I7), and EAC Intrinsic Safety (option code IM).

    (4)Only available with C6, E2, E5, I5, K5, KB, and E8 approval. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, or CT.

    (5)Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.


    More options :

    MR-J2S-10A

    MR-J2S-10B

    MR-J2S-20A

    MR-J2S-20B

    MR-J2S-40A

    MR-J2S-40B

    MR-J2S-60A

    MR-J2S-60B

    MR-J2S-70A

    MR-J2S-70B

    MR-J2S-100A

    MR-J2S-100B

    MR-J2S-200A

    MR-J2S-200B

    MR-J2S-350A

    MR-J2S-350B

    MR-J2S-500A

    MR-J2S-500B

    MR-J2S-700A

    MR-J2S-700B


    Rosemount 3051L Level Transmitter​ Information:

    ModelTransmitter type
    3051LLevel transmitter
    Pressure range
    2–250 to 250 in H2O (–621,60 to 621,60 mbar)
    3–1000 to 1000 in H2O (–2,48 to 2,48 bar)
    4–300 to 300 psi (–20,68 to 20,68 bar)
    Transmitter output
    A(1)4–20 mA with digital signal based on HART® Protocol
    FFOUNDATION™ Fieldbus Protocol
    W(2)PROFIBUS® PA Protocol
    X(3)Wireless (requires wireless options and engineered polymer housing)
    M(4)Low-power 1–5 Vdc with digital signal based on HART Protocol
    Process connection size, material, extension length (high side)
    CodeProcess connection sizeMaterialExtension length
    G0(5)2-in./DN 50/A316L SSTFlush mount only

    H0 (5)2-in./DN 50Alloy C-276Flush mount only
    J02-in./DN 50TantalumFlush mount only
    A0(5)3-in./DN 80316L SSTFlush mount
    A2(5)3-in./DN 80316L SST2-in./50 mm
    A4(5)3-in./DN 80316L SST4-in./100 mm
    A6(5)3-in./DN 80316L SST6-in./150 mm
    B0(5)4-in./DN 100316L SSTFlush mount
    B2(5)4-in./DN 100316L SST2-in./50 mm
    B4(5)4-in./DN 100316L SST4-in./100 mm
    B6(5)4-in./DN 100316L SST6-in./150 mm
    C0(5)3-in./DN 80Alloy C-276Flush mount
    C2(5)3-in./DN 80Alloy C-2762-in./50 mm
    C4(5)3-in./DN 80Alloy C-2764-in./100 mm
    C6(5)3-in./DN 80Alloy C-2766-in./150 mm
    D0(5)4-in./DN 100Alloy C-276Flush mount
    D2(5)4-in./DN 100Alloy C-2762-in./50 mm
    D4(5)4-in./DN 100Alloy C-2764-in./100 mm
    D6(5)4-in./DN 100Alloy C-2766-in./150 mm
    E03-in./DN 80TantalumFlush mount only
    F04-in./DN 100TantalumFlush mount only
    Mounting flange size, rating, material (high side)
    SizeRatingMaterial
    M2-in.ANSI/ASME B16.5 Class 150CS
    A3-in.ANSI/ASME B16.5 Class 150CS
    B4-in.ANSI/ASME B16.5 Class 150CS
    N2-in.ANSI/ASME B16.5 Class 300CS
    C3-in.ANSI/ASME B16.5 Class 300CS
    D4-in.ANSI/ASME B16.5 Class 300CS
    P2-in.ANSI/ASME B16.5 Class 600CS
    E3-in.ANSI/ASME B16.5 Class 600CS
    X(5)2-in.ANSI/ASME B16.5 Class 150316 SST
    F(5)3-in.ANSI/ASME B16.5 Class 150316 SST
    G(5)4-in.ANSI/ASME B16.5 Class 150316 SST
    Y(5)2-in.ANSI/ASME B16.5 Class 300316 SST
    H(5)3-in.ANSI/ASME B16.5 Class 300316 SST
    J(5)4-in.ANSI/ASME B16.5 Class 300316 SST
    Z(5)2-in.ANSI/ASME B16.5 Class 600316 SST
    L(5)3-in.ANSI/ASME B16.5 Class 600316 SST
    QDN 50PN 10-40 per EN 1092-1CS
    RDN 80PN 40 per EN 1092-1CS
    SDN 100PN 40 per EN 1092-1CS
    VDN 100PN 10/16 per EN 1092-1CS
    K(5)DN 50PN 10-40 per EN 1092-1316 SST
    T(5)DN 80PN 40 per EN 1092-1316 SST
    U(5)DN 100PN 40 per EN 1092-1316 SST
    W(5)DN 100PN 10/16 per EN 1092-1316 SST
    7(5)4 in.ANSI/ASME B16.5 Class 600316 SST
    1N/A10K per JIS B2238CS
    2N/A20K per JIS B2238CS
    3N/A40K per JIS B2238CS
    4(5)N/A10K per JIS B2238316 SST
    5(5)N/A20K per JIS B2238316 SST
    6(5)N/A40K per JIS B2238316 SST
    Seal fill fluid (high side)Specific gravityTemperature limits (ambient temperature of 70° F [21° C])
    DSilicone 2000.93–49 to 401 °F (–45 to 205 °C)
    FSilicone 200 for vacuum applications0.93For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.
    LDow Corning® 704 diffusion pump fluid1.0732 to 401 °F (0 to 205 °C)
    CD.C. Silicone 704 for vacuum applications1.07For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.
    ASYLTHERM XLT0.85–102 to 293 °F (–75 to 145 °C)
    HInert (halocarbon)1.85–49 to 320 °F (–45 to 160 °C)
    GGlycerin and water1.135 to 203 °F (–15 to 95 °C)
    NNeobee® M-200.925 to 401 °F (–15 to 205 °C)
    PPropylene glycol and water1.025 to 203 F (–15 to 95 °C)
    Low pressure side
    ConfigurationFlange adapterDiaphragm materialSensor fill fluid
    11(5)GageSST316L SSTSilicone
    21DifferentialSST316L SSTSilicone
    22(5)DifferentialSSTAlloy C-276Silicone
    2A(6)DifferentialSST316L SSTInert (halocarbon)
    2B(5) (6)DifferentialSSTAlloy C-276Inert (halocarbon)
    31(5)Tuned-system assembly with remote sealNone316L SSTSilicone (requires option code S1)
    O-ring
    AGlass-filled PTFE
    Housing materialConduit entry size
    AAluminum½–14 NPT
    BAluminumM20 x 1.5
    EAluminum, ultra low copper½–14 NPT
    FAluminum, ultra low copperM20 x 1.5
    JSST½–14 NPT
    KSSTM20 x 1.5
    P(7)Engineered polymerNo conduit entries
    D(8)Aluminum
    M(8)SST
    Wireless options (requires wireless output code X and Engineered Polymer Housing code P)
    Wireless transmit rate, operating frequency, and protocol
    WA3User configurable transmit rate, 2.4 GHz WirelessHART
    Antenna and SmartPower
    WP5Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
    Options (include with selected model number)
    Extended product warranty
    WR33-year limited warranty
    WR55-year limited warranty
    Plantweb control functionality(9)
    A01FOUNDATION Fieldbus Control Function Block Suite
    Plantweb diagnostic functionality
    DA0(20)Loop Integrity HART Diagnostic
    D01(9)FOUNDATION Fieldbus diagnostics suite
    Seal assemblies(10)
    S1Assembled to One Rosemount 1199 Seal
    Product certifications
    E8ATEX Flameproof and Dust Certification
    I1(11)ATEX Intrinsic Safety and Dust
    IAATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    N1ATEX Type n Certification and Dust
    K8ATEX Flameproof, Intrinsic Safety, Type n, and Dust (combination of E8, I1, and N1)
    E4(12)TIIS Flameproof
    E5FM Explosion-proof, Dust Ignition-proof
    I5(13)FM Intrinsically Safe, Nonincendive
    IEFM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K5FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2
    C6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
    I6(7)CSA Intrinsic Safety
    K6CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
    E7IECEx Flameproof, Dust Ignition-proof
    I7IECEx Intrinsic Safety
    N7IECEx Type n Certification
    K7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
    E2INMETRO Flameproof
    I2INMETRO Intrinsic Safety
    IBINMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K2INMETRO Flameproof, Intrinsic Safety
    E3China Flameproof
    I3China Intrinsic Safety
    N3China Type n
    EMTechnical Regulations Customs Union (EAC) Flameproof
    IMTechnical Regulations Customs Union (EAC) Intrinsic Safety
    KMTechnical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety
    KBFM and CSA Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
    KDFM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
    EP(14)Republic of Korea Flameproof
    IP(15)Republic of Korea Intrinsic Safety
    KP(16)Republic of Korea Flameproof, Intrinsic Safety
    Shipboard approvals(7)
    SBSAmerican Bureau of Shipping
    SBV(17)Bureau Veritas (BV)
    SDNDet Norske Veritas
    SLL(17)Lloyds Register (LR)
    Bolting material
    L4Austenitic 316 SST bolts
    L5ASTM A 193, grade B7M bolts
    L6Alloy K-500 Bolts
    L8ASTM A 193 Class 2, grade B8M bolts
    Display and interface options
    M4(18)LCD display with LOI
    M5LCD display
    Calibration certification
    Q4Calibration Certificate
    QPCalibration Certificate and tamper evident seal
    QG(19)Calibration Certificate and GOST Verification Certificate
    Material traceability certification
    Q8Material Traceability Certification per EN 10204 3.1
    Quality certification for safety(20)
    QSPrior-use certificate of FMEDA data
    QTSafety certified to IEC 61508 with certificate of FMEDA
    Toolkit total system performance reports
    QZSeal system performance calculation report
    Conduit electrical connector(6)
    GEM12, 4-pin, male connector (eurofast)
    GMA size Mini, 4-pin, male connector (minifast)
    Configuration buttons
    D4(20)Analog zero and span
    DZ(21)Digital zero trim
    Transient protection(6)(22)
    T1Transient protection
    Software configuration(21)
    C1

    Custom Software Configuration

    (For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see the Rosemount 3051 Wireless Configuration Data Sheet.)

    Low power output
    C20.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
    Alarm levels(20)
    C4(23)NAMUR alarm and saturation levels, high alarm
    CN(23)NAMUR alarm and saturation levels, low alarm
    CRCustom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
    CSCustom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
    CTRosemount Standard low alarm
    Conduit plug
    DO316 SST Conduit Plug
    Ground screw(6)(24)
    V5External ground screw assembly
    Lower housing flushing connection options
    Ring materialNumberSize (NPT)
    F1316 SST1¼–18 NPT
    F2316 SST2¼–18 NPT
    F3Alloy C-2761¼–18 NPT
    F4Alloy C-2762¼–18 NPT
    F7316 SST1½–14 NPT
    F8316 SST2½–14 NPT
    F9Alloy C-2761½–14 NPT
    F0Alloy C-2762½–14 NPT
    Lower housing intermediate gasket material
    S0No gasket for lower housing
    SY(25)Thermo-Tork® TN-9000
    NACE certificate(26)
    Q15Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
    Q25Certificate of compliance to NACE MR0103 for wetted materials
    HART Revision configuration(1) (requires HART protocol output code A)
    HR5Configured for HART Revision 5
    HR7Configured for HART Revision 7
    Typical model number: 3051L 2 A A0 D 21 A A F1

    Good Service in WTL:
    > We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
    > Please send your RFQ to get the latest price.
    > Normally, we will ship the items in 1-2 weeks after receive the payment.
    > We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
    > We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

    If needed, please contact us for specific prices.


    OUR MAIN BRAND:

    Quality 3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)