Sign In | Join Free | My himfr.com
Home > Pressure Temperature Transmitter >

3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure

Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure from wholesalers
     
    Buy cheap 3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure from wholesalers
    • Buy cheap 3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure from wholesalers
    • Buy cheap 3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure from wholesalers

    3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure

    Ask Lasest Price
    Brand Name : ROSEMOUNT
    Model Number : 3051CFADL060DCHPS2T100032AA1
    Price : Negotiate
    Payment Terms : T/T,PAYONEER
    Supply Ability : 20EA,6-8weeks
    Delivery Time : 8 WEEKS
    Certification : Does not supply
    • Product Details
    • Company Profile

    3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure

    3051CFADL060DCHPS2T100032AA1 Annubar Flow Meter Differential pressure


    Product Information Of : 3051CFADL060DCHPS2T100032AA1

    BrandEMERSON ROSEMOUNT
    Model3051CFADL060DCHPS2T100032AA1
    SUPPLY

    6-in

    SIZENo
    WeightDoes not supply

    The Rosemount 3051CFA Annubar Flow Meter uses the T-shaped sensor design that delivers best in class accuracy and performance while meeting the needs of diverse process applications, whether it is high accuracy for precision control or high strength for severe flow applications. Main capabilities include:
    ■Up to 1.8 percent of flow rate accuracy.
    ■Available in 2- to 96-in. (50 to 2400 mm) line.
    ■Fully assembled and leak tested for out-of-the-box installation.
    ■The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
    ■LOI with straightforward menus and built-in configuration buttons (option code M4).


    More options :

    3051CG3A02A1AB1H2L4M5K5

    3051CG4A02A1AB1H2L4M5K5

    3051CG5A02A1AB1H2L4M5K5

    3051CG4A02A1AB1H2L4M5I5

    3051CG4A02A1AB1H2L4M5E5

    3051CG3A02A1AB1H2L4M5I5

    3051CG1A02A1AB1H2L4M5E5

    3051CG2A02A1AB1H2L4M5E5

    3051CG3A02A1AB1H2L4M5E5

    3051CG5A02A1AB1H2L4M5E5

    3051CG1A02A1AB1H2L4M5I5

    3051CG2A02A1AB1H2L4M5I5


    A06B-6058-H004

    A06B-6058-H005

    A06B-6058-H006

    A06B-6045-H003

    A06B-0061-B503

    A06B-6045-H004

    A06B-6047-H003

    A06B-6047-H004

    A06B-6050-H112

    A06B-6050-H113

    A06B-0061-B203

    A06B-0371-B157

    A06B-0373-B175

    A06B-0123-B175

    A06B-0501-B002

    A06B-0502-B201


    Rosemount 3051CFA Annubar Flow Meter Information:

    ModelProduct description
    3051CFARosemount Annubar Flow Meter
    Measurement type
    DDifferential pressure
    Fluid type
    LLiquid
    GGas
    SSteam
    Line size
    0202-in. (50 mm)
    0252½-in. (63.5 mm)
    0303-in. (80 mm)
    0353½-in. (89 mm)
    0404-in. (100 mm)
    0505-in. (125 mm)
    0606-in. (150 mm)
    0707-in. (175 mm)
    0808-in. (200 mm)
    10010-in. (250 mm)
    12012-in. (300 mm)
    14014-in. (350 mm)
    16016-in. (400 mm)
    18018-in. (450 mm)
    20020-in. (500 mm)
    24024-in. (600 mm)
    30030-in. (750 mm)
    36036-in. (900 mm)
    42042-in. (1066 mm)
    48048-in. (1210 mm)
    60060-in. (1520 mm)
    72072-in. (1820 mm)
    78078-in (1950 mm)
    84084-in. (2100 mm)
    90090-in. (2250 mm)
    96096-in (2400 mm)
    Pipe I.D. range
    ZSpecify pipe I.D. and wall thickness
    Pipe material/mounting assembly material
    CCS (A105)
    S316 SST
    0No mounting (customer supplied)
    GChrome-moly grade F-11
    NChrome-moly grade F-22
    JChrome-moly grade F-91
    Piping orientation
    HHorizontal piping
    DVertical piping with downwards flow
    UVertical piping with upwards flow
    Annubar type
    PPak-Lok
    FFlanged with opposite side support
    LFlange-Lok
    GGear-drive Flo-Tap
    MManual Flo-Tap
    Sensor material
    S316 SST
    HAlloy C-276
    Sensor size
    1Sensor size 1 — line sizes 2- to 8-in. (50 to 200 mm)
    2Sensor size 2 — line sizes 6- to 96-in. (150 to 2400 mm)
    3Sensor size 3 — line sizes greater than 12-in. (300 mm)
    Mounting type
    T1Compression or threaded connection
    A1Class 150 RF ANSI
    A3Class 300 RF ANSI
    A6Class 600RF ANSI
    D1DN PN16 flange
    D3DN PN40 flange
    D6DN PN100 flange
    A9(1)Class 900 RF ANSI
    AF(1)Class 1500 RF ANSI
    AT(1)Class 2500 RF ANSI
    R1Class 150 RTJ flange
    R3Class 300 RTJ flange
    R6Class 600RTJ flange
    R9(1)Class 900 RTJ flange
    RF(1)Class 1500 RTJ flange
    RT(1)Class 2500 RTJ flange
    Opposite side support or packing gland
    0No opposite side support or packing gland (required for Pak-Lok and Flange-Lok models)
    Opposite side support – required for flanged models
    CNPT threaded opposite support assembly – extended tip
    DWelded opposite support assembly – extended tip
    Packing gland – required for Flo-Tap models
    Packing gland materialRod materialPacking material
    J(2)SST packing gland/cage nippleCSPTFE
    K(2)SST packing gland/cage nippleSSTPTFE
    L(2)SST packing gland/cage nippleCSGraphite
    N(2)SST packing gland/cage nippleSSTGraphite
    RAlloy C-276 packing gland/cage nippleSSTGraphite
    Isolation valve for Flo-Tap models
    0Not applicable or customer supplied
    1Gate valve, CS
    2Gate valve, SST
    5Ball valve, CS
    6Ball valve, SST
    Temperature measurement
    TIntegral RTD – not available with flanged model greater than Class 600
    0No temperature sensor
    RRemote Thermowell and RTD
    Transmitter connection platform
    3Direct-mount, integral 3-valve manifold– not available with flanged model greater than Class 600
    5Direct-mount, 5-valve manifold – not available with flanged model greater than Class 600
    7Remote-mount NPT connections (½-in. NPT)
    6Direct-mount, high temperature 5-valve manifold – not available with flanged model greater than Class 600
    8Remote-mount SW connections (½-in.)
    Differential pressure range
    10 to 25 in H2O (0 to 62,16 mbar)
    20 to 250 in H2O (0 to 621,60 mbar)
    30 to 1000 in H2O (0 to 2,48 bar)
    Transmitter output
    A(3)4–20 mA with digital signal based on HART® Protocol
    FFOUNDATION™ Fieldbus Protocol
    W(4)PROFIBUS® PA Protocol
    X(5)Wireless (requires wireless options and engineered polymer housing)
    M(6)Low-power 1–5 Vdc with digital signal based on HART Protocol
    Transmitter housing materialConduit entry size
    AAluminum½–14 NPT
    BAluminumM20 x 1.5
    JSST½–14 NPT
    EAluminum, ultra copper low½–14 NPT
    FAluminum, ultra copper lowM20 x 1.5
    KSSTM20 x 1.5
    P(7)Engineered polymerNo conduit entries
    D(8)Aluminum
    M(8)SST
    Transmitter performance class
    11.8 percent flow rate accuracy, 8:1 flow turndown, 5-yr. stability
    Wireless options (requires wireless output code X and Engineered Polymer Housing Code P)
    Wireless transmit rate, operating frequency, and protocol
    WA3User configurable transmit rate, 2.4 GHz WirelessHART
    Antenna and SmartPower
    WP5Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
    Options (include with selected model number)
    Extended product warranty
    WR33-year limited warranty
    WR55-year limited warranty
    Pressure testing(9)
    P1Hydrostatic testing with certificate
    PXExtended hydrostatic testing
    Special cleaning
    P2Cleaning for special services
    PACleaning per ASTM G93 Level D (section 11.4)
    Material testing
    V1Dye penetrant exam
    Material examination
    V2Radiographic examination
    Flow calibration
    W1Flow calibration (Average K)
    Special inspection
    QC1Visual and dimensional inspection with certificate
    QC7Inspection and performance certificate
    Surface finish
    RLSurface finish for low pipe Reynolds number in gas and steam
    RHSurface finish for high pipe Reynolds number in liquid
    Material traceability certification(10)
    Q8Material Traceability Certification per EN 10474:2004 3.1
    Code conformance(11)
    J2ANSI/ASME B31.1
    J3ANSI/ASME B31.3
    Materials conformance(12)
    J5NACE MR-0175 / ISO 15156
    Country certification
    J6European Pressure Directive (PED)
    J1Canadian Registration
    Installed in flanged pipe spool section
    H3Class 150 flanged connection with Rosemount standard length and schedule
    H4Class 300 flanged connection with Rosemount standard length and schedule
    H5Class 600 flanged connection with Rosemount standard length and schedule
    Instrument connections for remote mount options
    G2Needle valves, SST
    G6OS&Y gate valve, SST
    G1Needle valves, CS
    G3Needle valves, alloy C-276
    G5OS&Y gate valve, CS
    G7OS&Y gate valve, alloy C-276
    Special shipment
    Y1Mounting hardware shipped separately
    Special dimensions
    VMVariable mounting
    VTVariable tip
    VSVariable length spool section
    Plantweb control functionality(13)
    A01FOUNDATION Fieldbus control function block suite
    Plantweb diagnostic functionality
    DA0(14)Loop Integrity HART diagnostic
    D01(13)FOUNDATION Fieldbus diagnostics suite
    Product certifications
    E8ATEX Flameproof, Dust
    I1(15)ATEX Intrinsic Safety and Dust
    IAATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    N1ATEX Type n and Dust
    K8ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1, and N1)
    E5FM Explosion-proof, Dust Ignition-proof
    I5(16)FM Intrinsically Safe, Nonincendive
    IEFM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K5FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5)
    C6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
    I6(7)CSA Intrinsically Safe
    K6CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
    E7IECEx Flameproof, Dust Ignition-proof
    I7IECEx Intrinsic Safety
    N7IECEx Type n
    K7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
    E2INMETRO Flameproof
    I2INMETRO Intrinsic Safety
    IBINMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K2INMETRO Flameproof, Intrinsic Safety
    E3China Flameproof
    I3China Intrinsic Safety
    KBFM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
    KDCSA, FM, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
    Sensor fill fluid and O-ring options
    L1(17)Inert sensor fill fluid (silicone fill fluid is standard)
    L2Graphite-filled (PTFE) O-ring
    LA(17)Inert sensor fill fluid and graphite-filled (PTFE) O-ring
    Shipboard approvals(17)
    SBSAmerican Bureau of Shipping
    SLL(18)Lloyds Register (LR)
    Display and interface options
    M4(19)LCD display with LOI
    M5LCD display
    Transmitter calibration certification
    Q4Calibration certificate for transmitter
    Quality certification for safety(14)
    QSPrior-use certificate of FMEDA data
    QTSafety certified to IEC 61508 with certificate of FMEDA
    Transient protection(17) (20)
    T1Transient terminal block
    Manifold for remote mount option
    F23-valve manifold, SST
    F65-valve manifold, SST
    F13-valve manifold, CS
    F33-valve manifold, alloy C-276
    F55-valve manifold, CS
    F75-valve manifold, alloy C-276
    Lower power output
    C20.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
    Alarm levels(14)
    C4(21)NAMUR alarm and saturation levels, high alarm
    CN(21)NAMUR alarm and saturation levels, low alarm
    CRCustom alarm and saturation signal levels, high alarm
    CSCustom alarm and saturation signal levels, low alarm
    CTRosemount standard low alarm
    Configuration buttons
    D4(14)Analog zero and span
    DZ(22)Digital zero trim
    Ground screw(17)(23)
    V5External ground screw assembly
    HART Revision configuration (requires HART Protocol output code A)(3)
    HR5Configured for HART Revision 5
    HR7Configured for HART Revision 7
    Typical model number: 3051CFA D L 060 D C H P S 2 T1 0 0 0 3 2 A A 1

    Good Service in WTL:
    > We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
    > Please send your RFQ to get the latest price.
    > Normally, we will ship the items in 1-2 weeks after receive the payment.
    > We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
    > We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

    If needed, please contact us for specific prices.


    OUR MAIN BRAND:

    Quality 3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)