Sign In | Join Free | My himfr.com
Home > Redundant Power Supply Module >

Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042

Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042 from wholesalers
     
    Buy cheap Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042 from wholesalers
    • Buy cheap Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042 from wholesalers
    • Buy cheap Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042 from wholesalers

    Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042

    Ask Lasest Price
    Brand Name : Emerson
    Model Number : KJ3001X1-CA1
    Certification : CE
    Price : Contact us
    Payment Terms : T/T
    Supply Ability : 50
    Delivery Time : 3-5days
    • Product Details
    • Company Profile

    Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042

    Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042


    Redundant Power Supply Module

    • Emerson DeltaV Discrete Input Card (VE4001S2T2B4) Alt# KJ3001X1-CA1 or 12P1980X
    • Manufacturer: Emerson
    • Series: DeltaV
    • DI,32 CH,24 VDc,Dry Contact
    • Related Modules:KJ3001X1-CB1. KJ3002X1-BA1 KJ3002X1-BB1. KJ3002X1-BC1 KJ3002X1-BD1. KJ3002X1-BE1 KJ3002X1-BF1. KJ3002X1-BG2 KJ3003X1-BA1. KJ3003X1-EA1 KJ3004X1-BA1
    DeltaV Redundant Power Supply Module Models:
    KJ3002X1-BE1 12P0682X042 VE4005S2B2Analog Output 8-Channel 4-20mA HART Card
    KJ3002X1-BG1 VE4003S5B1 12P1731X012Thermocouple mV CARD
    KJ3001X1-CB1 VE4002S1T2B5 12P1985X032DO 32-Channel 24 VDC High-Side Card
    KJ3002X1-BA1 VE4003S2 12P0680X122Analog Input 8 Channel 4-20mA HART Card
    KJ3001X1-BH1 VE4002S2T1 12P0558X152DO 8-Ch 120/230 VAC Isolated
    KJ3001X1-BJ1 VE4002S1T2B2 12P0555X122DO 8-Channel 24 VDC High Side Card
    KJ1501X1-BC1 VE5008 12P2186X012System Dual DC Power Supply (DC/DC)
    KJ1501X1-BA2 VE5001 12P0677X062AC/DC System Power Supply
    KJ3001X1-BH1 VE4002S2T1 12P0558X152DO 8-Ch 120/230 VAC Isolated
    KJ3001X1-BD1 VE4001S3T2B2 12P0552X122Discrete Input 120VAC DRY CONTACT
    KJ3001X1-BG1 VE4002S1T1 12P0557X152DO 8-Channel 24 VDC Isolated Card
    KJ4002X1-BB1 VE4055S2C0 12P1728X042Right 8 Wide Vertical Carrier
    KJ4002X1-BC24 WIDE VERTICAL CARRIER TOP
    KJ4002X1-BE1 12P4048X012Top Extender Cable
    KJ4002X1-BF2 12P3866X012Bottom Extender Cable
    KJ4003X1-BE1 12P3839X022Vertical Left Side Extender
    KJ4003X1-BF1 12P3839X022Vertical Left Side Extender
    KJ4005X1-BA1 SE3051C0 12P4683POWER/CONTROLLER CARRIER
    KJ4010X1-BF1 12P0831X042Local Bus Left Extension
    KJ4010X1-BG1 12P0830X042Local Bus Right Extension
    KJ4101X1-BA1 12P1870X012IS 8 Wide Carrier
    KJ4101X1-BB1 12P1871IS LOCAL BUS ISOLATOR CARRIER
    KJ4101X1-BC1 12P1872X012IS Power Supply Carrier
    KJ4110X1-CA1 12P1873X012IS Extender Right-hand CARRIER
    KJ4110X1-CB1 12P1874X012IS Extender Right-hand CARRIER
    KL2101X1-BA1 12P4987X062Charm I/O CARD
    KL3002X1-BA1 12P4627X052DO 24 VDC High-Side
    KL3003X1-BA1 12P4632X082DI 24 VDC Dry Contact
    KL3021X1-BA1 12P4628X062AI 4-20 mA HART
    KL3022X1-BA1 12P4629X042AO 4-20 mA HART
    KL4101X1-BA1 12P4989CHARM I/O CARRIER
    KL4201X1-BA1 SE4601T07 12P4986X052Charm Base plate
    KL4502X1-BA1 12P4990X042Charm Terminal
    KJ4001X1-GG1 12P1812X022Thermocouple Terminal Block
    KJ4001X1-HB1 12P0830X072Local Bus Right Extender
    KJ4002X1-BA1 VE4055S1C0 12P1727X042Left 8 Wide Vertical Carrier
    KJ4001X1-CC1 12P0733X0324 Wire TX Terminal Block
    KJ1501X1-BK1 SE5009 12P4685System Power Supply 24 DC/DC
    KJ1700X1-BA1 VE6006 12P1710X012Media Converter
    KJ1710X1-BA1 VE6019 12P3305XSingle Port Fiber Switch
    KJ3001X1-BK1 VE4002S2T2 12P0556X142DO 8-Channel 120/230 VAC High Side
    KJ3001X1-CA1 VE4001S2T2B4 12P1980X042DI 32-Channel 24 VDC Dry Contact Card
    KJ3002X1-BB1 12P0683X072ANALOG OUTPUT 4-20mA
    KJ3002X1-BC1 VE4003S1B2 12P0681X072Analog Input Module Final Assy 4-20mA Card
    KJ3003X1-BA1 12P0914SERIAL INTERFACE CARD
    KJ3003X1-EA1 12P0921X032Interface Terminal Block


    Note:
    Refer to the product label for serial number and location and date of manufacture. Refer also to the wiring diagram on the left side of the card.

    Warning:

    This product has specific instructions for installation, removal and operation in hazardous areas. Refer to document 12P2046 "DeltaV Scalable Process System Zone 2 Installation Instructions". Other installation instructions are available in the "Installing Your DeltaV Automation System" manual.

    Description:


    a.Hazardous Atmosphere

    Nemko No. 02ATEX431U
    EEx nA IIC T4
    b.Power Specifications
    LocalBus power rating:12 VDC at 75 mA
    Field circuit rating:24 VDC at 150 mA
    Bussed field power rating:24 VDC at 5 mA/channel
    c.Environmental Specifications
    Ambient Temperature0 to 60℃
    Shock10g ½ Sinewave for 11 msec
    Vibration
    1mm Peak to Peak from 5 to 16Hz;
    0.5g from 16 to 150Hz
    Airborne Contaminants
    ISA-S71.04 –1985 Airborne
    Contaminants Class G3
    Relative Humidity
    5 to 95% Non-Condensing IP 20
    Rating
    Terminal block key positionB3


    d.Removal and Insertion

    Field power supplied to this device, either at the field terminal or as bussed field power through the carrier, must be removed before removing or connecting the device.
    This unit may be removed or inserted while system power is energized under the following conditions:
    (Note:Only one unit at a time may be removed or inserted with system power energized.)
    •When used with KJ1501X1-BC1 System Dual DC/DC Power Supply operating on either 24VDC or 12VDC input power, The primary circuit wiring inductance less than 23 uH, or a certified supply with an open circuit voltage, Ui of 12.6VDC and an Lo of less than 23 uH (including wire inductance).
    •Non sparking field circuits MUST be deenergized before removing and inserting this product.
    A terminal block fuse may NOT be removed with field power energized for non-sparking circuits.
    A rotary keying system ensures compatibility between I/O cards and terminal blocks after installation is complete. The terminal block must have the keys set for the I/O card with which it is used.

    e.Maintenance and Adjustment

    This unit contains no user serviceable parts and should not be disassembled for any reason.
    Calibration is not required.


    Our advantage Products:


    【Honeywell】Module DCS / PLC

    【Emerson / Delta V】Module
    【ABB】Input Output Module

    【AB】Module / Touch Screen

    【Rosemount】Pressure and Temperature Transmitter

    【Yokogawa】Pressure Transmitter

    【Yaskawa】Servo Drive / Servo Motor
    【GE/Fanuc】IC69 Series PLC

    【Mitsubishi】Servo Drive / Servo Motor
    (Modicon,SMC,SICK,NORGREN,Siemens etc.)


    Company Introduction

    Quality Emerson Redundant Dry Contact Module KJ3001X1-CA1 Power Supply VE4001S2T2B4 12P1980X042 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)