    Brand Name : Mitsubishi
    Model Number : FR-A820-3.7K-1
    Certification : CE
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 100
    Delivery Time : 3-5 days
    • Product Details
    • Company Profile

    Mitsubishi FR-A820-3.7K-1 General-Purpose Inverter FREQROL-A800

    Mitsubishi FR-A820-3.7K-1 General-Purpose Inverter FREQROL-A800

    Product Description:

    Motor Specifications

    The motor capacity requirement for this particular application is 3.7 kW. The input voltage class is specified as three-phase 200 V.

    The output specification is three-phase with a capacity of 6.7 kVA. The dimensions of the motor are as follows: height of 260 mm, width of 150 mm, and depth of 140 mm. The motor also comes with a protective structure.

    The output rated current is 17.5 A and the output rated power supply is three-phase 200-240 V.

    Rated (Standard Structure Models) 200 V Class:

    Type Name FR-A820-[](-E)(GF)0.4 K0.75 K1.5 K2.2 K3.7 K18.5 K37 K45 K55 K75 K90 K
    0004600077001050016700250009300187002330031600380004750
    Applicable Motor Capacity
    (kW) ∗1
    SLD0.751.52.23.75.52245557590/110132
    LD0.751.52.23.75.52245557590110
    ND (Initial Setting)0.40.751.52.23.718.53745557590
    HD0.2∗20.40.751.52.2153037455575
    OutputRated Capacity
    (kVA) ∗3
    SLD1.82.946.410357189120145181
    LD1.62.73.75.88.8326581110132165
    ND (Initial Setting)1.11.934.26.729556782110132
    HD0.61.11.934.22344556782110
    Rated Current
    (A)
    SLD4.67.710.516.72593187233316380475
    LD4.279.615.22385170212288346432
    ND (Initial Setting)3581117.576145175215288346
    HD1.53581161115145175215288
    Overload Current
    Rating ∗4
    SLD110% for 60 sec, 120% for 3 sec (inverse time characteristics), ambient temperature 40°C
    LD120% for 60 sec, 150% for 3 sec (inverse time characteristics), ambient temperature 50°C
    ND (Initial Setting)150% for 60 sec, 200% for 3 sec (inverse time characteristics), ambient temperature 50°C
    HD200% for 60 sec, 250% for 3 sec (inverse time characteristics), ambient temperature 50°C
    Rated Voltage∗53-phase 200 to 240 V
    Regenerative BrakingBrake TransistorBuilt-inFR-BU2 (Option)
    Maximum Brake Torque ∗7150% Torque, 3% ED ∗6100% Torque / 3% ED ∗620% Torque / Continuous10% Torque / Continuous
    FR-ABR
    (With Option Selected)
    150% Torque, 10% ED100% Torque / 10% ED100% Torque
    / 6% ED
    -----
    Power SupplyRated Input
    AC Voltage / Frequency
    3-phase 200 to 240 V, 50 Hz / 60 Hz
    Allowable AC Voltage Variation170 to 264 V, 50 Hz / 60 Hz
    Allowable Frequency Variation±5%
    Rated Input
    Current (A)
    ∗8
    Without DC ReactorSLD5.38.913.219.731.3115221269---
    LD58.312.218.328.5106207255---
    ND (Initial Setting)3.96.310.614.122.696.3181216266--
    HD2.33.96.310.614.180150181216--
    With DC ReactorSLD4.67.710.516.72593187233316380475
    LD4.279.615.22385170212288346432
    ND (Initial Setting)3581117.576145175215288346
    HD1.53581161115145175215288
    Power Supply Facility
    Capacity (kVA)
    ∗9
    Without DC ReactorSLD23.457.5124484103---
    LD1.93.24.7711417997---
    ND (Initial Setting)1.52.445.48.6376982101--
    HD0.91.52.445.430576982--
    With DC ReactorSLD1.82.946.410357189120145181
    LD1.62.73.75.88.8326581110132165
    ND (Initial Setting)1.11.934.26.729556782110132
    HD0.61.11.934.22344556782110
    Protective Structure (IEC 60529) ∗10Closed Type (IP20)Open Type (IP00)
    Cooling MethodSelf-coolingForced air cooling
    Approx. Weight (kg)2.02.23.33.33.3154242547474

    ∗1 The maximum applicable capacity assumes that Mitsubishi Electric’s standard 4-pole motor is used.
    ∗2 With the 0.2 kW motor, only the V/F control can be applied.
    ∗3 The rated output capacity assumes an output voltage of 220 V.
    ∗4 The percent value of the rated overload current displays the ratio for the rated output current of the inverter.
    With repeated use, you must wait until the inverter and motor return to a temperature at 100% load or a lower temperature between use.
    ∗5 The maximum output voltage never exceeds the power supply voltage. The maximum output voltage can be changed within its range of settings.
    However, the wave crest value of the inverter output voltage waveform is roughly √2 times that of the power supply voltage.
    ∗6 With a built-in brake resistor
    ∗7 Value based on the ND rating.
    ∗8 The rated input current is the value at the rated output current. The rated input current varies depending on the value of power supply impedance (including the impedance of the input reactor and wires).
    ∗9 The value of power supply capacity is the value at the rated output current. It varies depending on the value of power supply impedance (including the impedance of the input reactor and wires).
    ∗10 FR-DU08: IP40 (excluding the PU connector)

    Rated (Standard Structure Models) 400 V Class

    ∗1 The maximum applicable capacity assumes that Mitsubishi Electric’s standard 4-pole motor is used.

    ∗2 With the 0.2 kW motor, only the V/F control can be applied.
    ∗3 The rated output capacity assumes an output voltage of 440 V.
    ∗4 The percent value of the rated overload current displays the ratio for the rated output current of the inverter.
    With repeated use, you must wait until the inverter and motor return to a temperature at 100% load or a lower temperature between use.
    ∗5 The maximum output voltage never exceeds the power supply voltage. The maximum output voltage can be changed within its range of settings.
    However, the wave crest value of the inverter output voltage waveform is roughly √2 times that of the power supply voltage.
    ∗6 With a built-in brake resistor
    ∗7 Value based on the ND rating.
    ∗8 The rated input current is the value at the rated output current. The rated input current varies depending on the value of power supply impedance (including the impedance of the input reactor and wires).
    ∗9 The value of power supply capacity is the value at the rated output current. It varies depending on the value of power supply impedance (including the impedance of the input reactor and wires).
    ∗10 FR-DU08: IP40 (excluding the PU connector)
    ∗11 If 480 V is exceeded, the Pr. 977, "Input Voltage Mode Selection," must be set.
    ∗12 The regenerative brake capacity can be improved using a commercially available brake resistor. For further details, please contact the Mitsubishi Sales Office.

    Applications:

    Effective Vector Control Option Required

    The displayed protection functions can vary depending on the option(s) installed. To ensure proper function, the option to support vector control must be installed.

    PM Sensorless Vector Control

    If you have selected PM sensorless vector control, please refer to page 211 for additional information.

    Torque Limitation Level

    Please note that for models 3 FR-A820-5.5 K (00340) or larger and FR-A840-5.5 K (00170) or larger, the default value is limited to 150% due to torque limitations.

    Standard Structure and IP55 Compatible Models

    Protection functions are effective only on standard structure models and IP55 compatible models. Please refer to the product specifications to determine compatibility.

    Protection Function Limitations

    Please be aware that certain protection functions may not work from the initial state or may only work on specific models. For example, function 6 works only on standard structure models, while function 7 works only on IP55 compatible models.

    Temperature Limitations

    While it may be safe to expose the unit to temperatures outside of the specified range for short periods, such as during shipping, please adhere to the specified limits when in use.

    Altitude Limitations

    If installing the unit at an altitude exceeding 1,000 m (up to 2,500 m), please note that the rated current must be reduced by 3% every 500 m.

    Vibration Limitations

    Please note that vibrations greater than 2.9 m/s2 are not recommended for FR-A840-160 K (04320) or larger models.

    FR-A800-E Function Limitations

    Function 11 works only on the FR-A800-E model.

    Packing and Shipping:

    Product Packaging:

    The Variable Frequency Inverter product will be securely packaged to ensure that it arrives in pristine condition. The product will be placed in a sturdy cardboard box with sufficient padding to prevent any damage during transit.

    Shipping:

    Once your order has been processed, the Variable Frequency Inverter product will be shipped to your desired location using a reliable shipping service. The shipping cost will be calculated based on the weight and destination of the package. You will be provided with a tracking number so you can monitor the progress of your shipment.




    Our Brands:


    Quality Mitsubishi FR-A820-3.7K-1 General-Purpose Inverter FREQROL-A800 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)