    YOKOGAWA EJA 110A-EMS4A-24DC/D3 Model EJA110A Differential Pressure Transmitter

    Ask Lasest Price
    Brand Name : YOKOGAWA
    Model Number : EJA 110A-EMS4A-24DC/D3
    Price : Contact me
    Payment Terms : TT
    Supply Ability : Contact me
    Delivery Time : 3~5 days
    • Product Details
    • Company Profile

    YOKOGAWA EJA 110A-EMS4A-24DC/D3 Model EJA110A Differential Pressure Transmitter

    YOKOGAWA EJA 110A-EMS4A-24DC/D3 Model EJA110A Differential Pressure Transmitter

    Product Description(for EJA 110A-EMS4A-24DC/D3 )

    Specifications
    The high performance differential pressure transmitter model EJA110A can be used to measure liquid, gas,or steam flow as well as liquid level, density and pressure. It outputs a 4 to 20 mA DC signal corre- sponding to the measured differential pressure. ModelEJA110A also features remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM CS™ or XL™ or HART ® 275 host.
    STANDARD SPECIFICATIONS
    Refer to GS 01C22T02-00E for F OUNDATION Fieldbus communication type and GS 01C22T03-00E for PROFIBUS PA communication type marked with “.” PERFORMANCE SPECIFICATIONS Zero-based calibrated span, linear output, wetted parts material code ‘S’ and silicone oil. Reference Accuracy of Calibrated Span (including the effects of zero-based linearity, hyster- esis, and repeatability)
    0.065 % of Span
    For spans below X
    [0.015 + 0.05 ] % of Span
    X
    Span
    where X equals:
    Capsule X kPa {inH2
    O}
    L 3 {12}
    M 10 {40}
    H 100 {400}
    V 1.4 MPa {200 psi}

    Features (for EJA 110A-EMS4A-24DC/D3 ):

    tatic Pressure Effects
    Total Effects per Change
    L capsule
    [0.07 % Span+0.052 % URL] per 3.4 MPa {500 psi}
    M, H and V capsules
    [0.1% Span+0.028 % URL] per 6.9 MPa {1000 psi}
    Effect on Zero (can be corrected at line pres-
    sure)
    L capsule
    [0.02 % Span+0.052 % URL] per 3.4 MPa {500 psi}
    M, H and V capsules
    0.028 % of URL per 6.9 MPa {1000 psi}
    Overpressure Effects (M, H and V capsules)
    0.03 % of URL per 16 MPa {2300 psi}
    Stability
    0.1 % of URL per 60 months (M, H and V capsules)
    0.2 % of URL per 12 months (L capsule)
    Power Supply Effects “”
    0.005 % per Volt (from 21.6 to 32 V DC, 350 )

    Technical Parameters (for EJA 110A-EMS4A-24DC/D3 ):

    FUNCTIONAL SPECIFICATIONS
    Span & Range Limits
    Measurement
    Span/Range
    L
    M
    H
    0.5 to 10
    -100 to 100
    -5 to 5 kgf/cm 2
    Span
    Span
    Span
    Range
    Range
    Range
    kPa
    2 to 40
    -40 to 40
    -400 to 400
    4 to 400
    -10 to 10
    1 to 100
    5 to 500
    -500 to 500
    inH 2O(/D1)
    20 to 2000
    -2000 to 2000
    mbar(/D3)
    5 to 100
    -1000 to 1000
    -100 to 100
    10 to 1000
    50 to 5000
    -5000 to 5000
    mmH 2O(/D4)
    50 to 1000
    -1000 to 1000
    100 to 10000
    -10000 to 10000
    0.05 to 5 kgf/cm 2
    T01E.EPS
    V* 1 Span
    Range -5 to 140 kgf/cm 2
    0.14 to 14 MPa
    -0.5 to 14 MPa
    20 to 2000 psi
    -71 to 2000 psi
    1.4 to 140 bar
    -5 to 140 bar

    Applications (for EJA 110A-EMS4A-24DC/D3 ):

    he sum of the amplifier and capsule damping time
    constant must be used for the overall time constant.
    Amp damping time constant is adjustable from 0.2 to
    64 seconds.
    Capsule (Silicone Oil) L M H and V
    Time Constant (approx. sec) 0.4 0.3 0.3
    Ambient Temperature Limits
    (approval codes may affect limits)
    -40 to 85 ˚C (-40 to 185 ˚F)
    -30 to 80 ˚C (-22 to 176 ˚F) with LCD Display
    Process Temperature Limits
    (approval codes may affect limits)
    -40 to 120 ˚C (-40 to 248 ˚F)
    Ambient Humidity Limits
    5 to 100 % RH @ 40 ˚C (104 ˚F)
    Working Pressure Limits (Silicone Oil)
    Maximum Pressure Limit
    Capsule Wetted parts material code
    H, M, T, A, D, and B S
    L 3.5 MPa {500 psi} 16 MPa {2300 psi}
    M, H, and V 16 MPa {2300 psi} 16 MPa {2300 psi

    Support and Services(for EJA 110A-EMS4A-24DC/D3 ):

    Our Pressure Temperature Transmitter product comes with comprehensive technical support and services to ensure optimal performance and reliability.

    We offer:

    • Installation assistance to help you get started with your device
    • 24/7 technical support to address any issues you may encounter
    • Annual maintenance services to keep your device in top working condition
    • Calibration services to ensure accurate and consistent readings
    • Repair services to quickly resolve any problems with your device

    Our team of experts is dedicated to providing exceptional customer service and support for all of your Pressure Temperature Transmitter needs.

    FAQ (for EJA 110A-EMS4A-24DC/D3 ):

    Q1: What is the brand name of the Pressure Temperature Transmitter?

    A1: The brand name of the Pressure Temperature Transmitter is YOKOGAWA

    Q2: What is the model number of the Pressure Temperature Transmitter?

    A2: The model number of the Pressure Temperature Transmitter is EJA 110A-EMS4A-24DC/D3

    Q3: Where is the Pressure Temperature Transmitter manufactured?

    A3: The Pressure Temperature Transmitter is manufactured in theJanpan

    Q4: Does the Pressure Temperature Transmitter have any certification?

    A4: Yes, the Pressure Temperature Transmitter is CE certified.

    Q5: What is the minimum order quantity for the Pressure Temperature Transmitter?

    A5: The minimum order quantity for the Pressure Temperature Transmitter is 1.

    Q6: What is the price of the Pressure Temperature Transmitter?

    A6: Please contact us for the price of the Pressure Temperature Transmitter.

    Q7: How is the Pressure Temperature Transmitter packaged?

    A7: The Pressure Temperature Transmitter is packaged in its original packaging.

    Q8: How long does it take for delivery of the Pressure Temperature Transmitter?

    A8: The delivery time for the Pressure Temperature Transmitter is 3 to 5 days.

    Q9: What are the payment terms for the Pressure Temperature Transmitter?

    A9: The payment terms for the Pressure Temperature Transmitter are TT.

    Q10: What is the supply ability of the Pressure Temperature Transmitter?

    A10: Please contact us for the supply ability of the Pressure Temperature Transmitter.

    Quality YOKOGAWA EJA 110A-EMS4A-24DC/D3 Model EJA110A Differential Pressure Transmitter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)